XLAL function call failed (I/O error): ERROR: data missing at end of SFT

Ananas
Ananas
Joined: 22 Jan 05
Posts: 272
Credit: 2500681
RAC: 0
Topic 197827

2014-11-26 07:02:11.7656 (1384) [normal]: Reading input data ... ERROR: data missing at end of SFT#0 (GPS 949469977.000000) expected bin 285278, bin 285209 read from file '..\..\projects\einstein.phys.uwm.edu\h1_0158.40_S6GC1'

on h1_0158.35_S6GC1__S6BucketFU1UB_00469712_0

p.s.: Xeon with Win XP x64

p.p.s.: Got another one for the same application and that one seems to start properly, so it is most likely a damaged input file for this specific workunit / container file. File size on my HDD is 8445248 bytes (h1_0158.40_S6GC1)

Ananas
Ananas
Joined: 22 Jan 05
Posts: 272
Credit: 2500681
RAC: 0

XLAL function call failed (I/O error): ERROR: data missing at en

Some others failed too (the list includes the one above) :

h1_0189.10_S6GC1
h1_0160.20_S6GC1
h1_0158.40_S6GC1
h1_0137.95_S6GC1
h1_0145.65_S6GC1
h1_0172.50_S6GC1
h1_0215.15_S6GC1
h1_0148.75_S6GC1
h1_0172.35_S6GC1
h1_0144.10_S6GC1

No trouble with :

h1_0101.80_S6GC1
h1_0147.70_S6GC1
h1_0068.00_S6GC1
h1_0150.70_S6GC1
h1_0110.85_S6GC1
h1_0097.10_S6GC1

Others have the same errors, so it is not my host that causes them.
Linux hosts have the same problem so it is not a CR/LF and/or EOF character issue.

Bernd Machenschalk
Bernd Machenschalk
Moderator
Administrator
Joined: 15 Oct 04
Posts: 4273
Credit: 245214851
RAC: 12924

Thanks for reporting. There

Thanks for reporting. There is indeed something wrong with the workunits.

BM

BM

Sebastian M. Bobrecki
Sebastian M. Bo...
Joined: 20 Feb 05
Posts: 63
Credit: 1529583285
RAC: 81

Same here:

Conan
Conan
Joined: 19 Jun 05
Posts: 172
Credit: 7178839
RAC: 1888

This error came up over at

This error came up over at Albert and was causing a lot of failures.

It was fixed in version 1.05 (Albert work unit number) as I had no trouble with them when this version was released, on both Windows 32 bit and Linux 64 bit.

Conan

Oliver Behnke
Oliver Behnke
Moderator
Administrator
Joined: 4 Sep 07
Posts: 946
Credit: 25167626
RAC: 19

We stopped sending out those

We stopped sending out those workunits and will analyze the issue...

Best,
Oliver

 

Einstein@Home Project

archae86
archae86
Joined: 6 Dec 05
Posts: 3145
Credit: 7057284931
RAC: 1601723

Probably this is just how the

Probably this is just how the same error looks on a Windows 7 host, but as it looks a little different I'll post a link to it:

http://einsteinathome.org/task/467842656

The first obviously alarming line reads:
The target internal file identifier is incorrect.

but a bit later one does see:2014-11-26 06:13:03.9774 (5004) [normal]: Reading input data ... ERROR: data missing at end of SFT#0 (GPS 949469977.000000) expected bin 308651, bin 308609 read from file '..\..\projects\einstein.phys.uwm.edu\h1_0171.40_S6GC1'

which matches other error reports posted here closely.

Bernd Machenschalk
Bernd Machenschalk
Moderator
Administrator
Joined: 15 Oct 04
Posts: 4273
Credit: 245214851
RAC: 12924

RE: The first obviously

Quote:
The first obviously alarming line reads:
The target internal file identifier is incorrect.

This isn't very alarming. It's just the BOINC Client trying to interpret the applications exit code (114) as if it was a Windows system error (which it usually isn't).

BM

BM

Comment viewing options

Select your preferred way to display the comments and click "Save settings" to activate your changes.