It is hard to see in the following list with all items in one column, but two of the WU I received were ignored and skipped. WU received later were chosen instead.
Look at WUs 367506 next to the last and 348852 fifth down. These are the skipped ones.
There is one similarity. Both of these two WUs were sent about one minute before another WU was sent. Is there a bug that causes two WUs to be sent within a minute of each other and when this is done, the first received is ignored?
I did not that when these pairs of WUs were recieved, the server did not respond on the request for more work. A minute later, a second request was made. The server apparently filled both requests.
1455858
409107
27 Feb 2005 9:11:09 UTC
6 Mar 2005 9:11:09 UTC
In Progress
Unknown
New
---
---
---
1427692
402793
26 Feb 2005 15:35:20 UTC
5 Mar 2005 15:35:20 UTC
In Progress
Unknown
New
---
---
---
1408337
398281
26 Feb 2005 0:05:54 UTC
27 Feb 2005 9:11:09 UTC
Over
Success
Done
54,496.67
71.55
pending
1393701
394865
25 Feb 2005 8:35:55 UTC
26 Feb 2005 15:35:20 UTC
Over
Success
Done
54,500.77
71.55
pending
1384772
348852
25 Feb 2005 8:34:47 UTC
4 Mar 2005 8:34:47 UTC
In Progress
Unknown
New
---
---
---
1318105
377427
24 Feb 2005 15:27:36 UTC
26 Feb 2005 0:05:54 UTC
Over
Success
Done
54,482.45
71.53
pending
1297899
372767
23 Feb 2005 21:22:02 UTC
25 Feb 2005 8:34:47 UTC
Over
Success
Done
54,559.61
71.63
99.38
1297890
372765
23 Feb 2005 4:59:19 UTC
24 Feb 2005 15:27:36 UTC
Over
Success
Done
54,612.03
73.82
98.26
1287423
370371
22 Feb 2005 12:02:03 UTC
23 Feb 2005 21:22:02 UTC
Over
Success
Done
54,699.13
73.94
102.43
1285546
369944
21 Feb 2005 20:04:49 UTC
23 Feb 2005 4:59:18 UTC
Over
Success
Done
54,538.41
73.72
85.38
1275101
367506
21 Feb 2005 20:03:40 UTC
28 Feb 2005 20:03:40 UTC
In Progress
Unknown
New
---
---
---
1188564
348853
20 Feb 2005 6:34:43 UTC
22 Feb 2005 12:02:02 UTC
Over
Success
Done
54,540.33
73.72
pending
Copyright © 2024 Einstein@Home. All rights reserved.
WU Are Skipped
)
Boinc Version 4.19 – Einstein 4.79 Work Units Downloaded 113 Units skipped 12
The skipping of work units certainly happens on most of my machines. A work unit is downloaded but never processed, no error is returned to the project. In most cases other machines have been able to process the unit successfully.
1365366 388301 24 Feb 2005 14:16:32 UTC 25 Feb 2005 15:57:10 UTC Over Success Done 20,297.47 91.45 pending
1365342 388296 24 Feb 2005 14:15:22 UTC 3 Mar 2005 14:15:22 UTC In Progress Unknown New --- --- ---
H1_0457.9__0458.0_0.1_T02_Test02 skipped but Over Success Done on two machines
-------------------------------------------------------------------------------------------------------
1377034 391019 24 Feb 2005 22:20:37 UTC 26 Feb 2005 7:39:18 UTC Over Success Done 22,427.44 82.99 85.01
1368428 389001 24 Feb 2005 22:19:27 UTC 3 Mar 2005 22:19:27 UTC In Progress Unknown New --- --- ---
H1_1082.4__1082.6_0.1_T02_Test02 skipped but Over Success Done on two machines