From my logfile below you can see that a WU called H1_0738.4__0738.8_0.1_T14_Test02 was worked on and sent in.
2/25/2005 11:44:03 PM||Starting BOINC client version 4.24 for windows_intelx86
2/25/2005 11:44:03 PM|Einstein@Home|Host location: home
2/25/2005 11:44:03 PM|Einstein@Home|Using your default project prefs
2/25/2005 11:44:03 PM|Einstein@Home|Host ID is 32132
2/25/2005 11:44:03 PM||General prefs: from Einstein@Home (last modified 2005-02-21 07:21:41)
2/25/2005 11:44:03 PM||General prefs: using your defaults
2/25/2005 11:44:03 PM|Einstein@Home|Resuming computation for result H1_0738.4__0738.7_0.1_T12_Test02 using einstein version 4.79
2/25/2005 11:44:03 PM|Einstein@Home|Resuming computation for result H1_0738.4__0738.8_0.1_T14_Test02 using einstein version 4.79
2/26/2005 1:36:46 AM|Einstein@Home|Computation for result H1_0738.4__0738.7_0.1_T12_Test02 finished
2/26/2005 1:36:46 AM|Einstein@Home|Starting result H1_0738.4__0738.9_0.1_T16_Test02 using einstein version 4.79
2/26/2005 1:36:48 AM|Einstein@Home|Started upload of H1_0738.4__0738.7_0.1_T12_Test02
2/26/2005 1:36:51 AM|Einstein@Home|Finished upload of H1_0738.4__0738.7_0.1_T12_Test02
2/26/2005 1:36:51 AM|Einstein@Home|Throughput 41360 bytes/sec
2/26/2005 1:38:25 AM|Einstein@Home|Computation for result H1_0738.4__0738.8_0.1_T14_Test02 finished
2/26/2005 1:38:25 AM|Einstein@Home|Starting result H1_0738.4__0738.6_0.1_T17_Test02_1 using einstein version 4.79
2/26/2005 1:38:26 AM|Einstein@Home|Started upload of H1_0738.4__0738.8_0.1_T14_Test02
2/26/2005 1:38:57 AM|Einstein@Home|Finished upload of H1_0738.4__0738.8_0.1_T14_Test02
2/26/2005 1:38:57 AM|Einstein@Home|Throughput 31175 bytes/sec
2/26/2005 7:49:59 AM|Einstein@Home|Sending request to scheduler: http://einstein.phys.uwm.edu/EinsteinAtHome_cgi/cgi
2/26/2005 7:50:01 AM|Einstein@Home|Scheduler RPC to http://einstein.phys.uwm.edu/EinsteinAtHome_cgi/cgi succeeded
2/26/2005 7:50:01 AM|Einstein@Home|Host location: home
2/26/2005 7:50:01 AM|Einstein@Home|Using your default project prefs
But when checking if it actually was registered as sent in I discover it isn't.
http://einsteinathome.org/workunit/386730
Copyright © 2024 Einstein@Home. All rights reserved.
Work Units sent in does not appear to be registered
)
And I have exactly the same phenomenon on my Linux machine, 21835.
So to sum it up, I have three machines working on einstein@home now wasting electricity ...
Seems to be the same for me
)
Seems to be the same for me on
http://einsteinathome.org/host/25982
I'm missing 2 registered results, 1 from a day ago and one some days ago
BTW: and contact to seti is currently lost. There are 4 unist in the queue
and I can't get new ones.
Currently no fun
> And I have exactly the same phenomenon on my Linux machine, 21835.
>
> So to sum it up, I have three machines working on einstein@home now wasting
> electricity ...
>
The Results aren't lost.
)
The Results aren't lost. There are two steps that need to be done for a result after it has finished: 1. the Result file hast to be uploaded (which, accoding to the messages, has happened) and 2. the Result has to be reported, which may happen on the next contact to the server. The client normally decides when it is time to do this based on the deadline, however you can manually initiate a report of all finished Results by chosing the "Update Project" function.
BM
BM
My god, that is
)
My god, that is brilliant!
I'm pretty sure I updated the Windows machine before checking this.